Optigo PF27MC

Optigo PF27MC

Optigo PF27MC are cubic commercial air coolers suitable for the safe use of A3 refrigerants such as R290 (propane).
General application for Optigo PF27MC are in small to medium-sized cooling rooms.

The Optigo PF27MC series machines use the same heat exchange components as the corresponding Optigo FMC series models and provide the same performance. The Optigo PF27MC series machines can work with HFC category A1 refrigerants.

Main characteristics Optigo PF27MC

Standard configuration

  • High-efficiency coil manufactured from internally grooved Cu tubes and louvered aluminium fins.

  • Standard fin spacings: 4.5, 6, 7 mm.

  • Durable galvanized steel casing, powder coated RAL 9003.

  • Dismountable and openable casing for cleaning and inspecting purposes.

  • 1 to 4 fans fitted with 1 to 4 fans fitted with high efficiency single speed Ø 275 mm EC fan motors drawing through the coil. Power supply 230/50/1.

  • Fan motors wired to a central connection box.


Options

For a full overview of all available options and additional technical specifications please refer to the product leaflet. Optigo PF27MC

How it works

Alfa LU-VE finned coil air heat exchangers have been designed to achieve an optimized exchange of thermal energy between air and a refrigerant or fluid. The ‘heart’ of our air heat exchangers is the finned coil, built up from a circuit of interconnected tube serpentines and fins to increase the heat exchanging surface. Thanks to the combination of key design variables (coil materials, coil geometry, casing design, fan type), air units are very versatile heat exchangers with a great variety of applications in many industries. Alfa LU-VE supplies finned coil air heat exchanger products for a wide variety of applications.

Air coolers & air-cooled condensers

Air coolers and air-cooled condensers are key components in air cooling and air conditioning systems. On the refrigerant side the most common media are a brine or an evaporating refrigerant like HFO/HFC, ammonia or CO2. A chilled brine may be supplied from a chiller that is potentially located far away, but a liquified refrigerant must come from a nearby condensing unit. When an evaporating refrigerant is used, the cooling coil is the evaporator in the vapour-compression refrigeration cycle (‘direct expansion’ or ‘DX’ system).

Specifications
  • Refrigerants: HFC A1, A2L, A3
  • Design pressure: 24 bar
  • Capacity (SC2 with R404): 1.07 up to 6.9 kW
  • Capacity (Tair = 2.5 °C, Tevap = - 7.5 °C with R290): 1.40 up to 9.01 kW
  • Air flow: 900 up to 10,400 m³/h
  • Min. room temperature: - 25 °C
Selection tools
These air heat exchanger products can be configured and selected using our online selection tool Plair.
Mobile app for iOS & Android to calculate the expected heat load for your cold room.
Plus
  • Designed for safe operation with A3 refrigerants
  • Energy efficient EC fans
  • Compact size for efficient use of cold room space

Applications